Discontinuation rates of intrauterine contraception due to unfavourable bleeding: a systematic review

Merz, M (通讯作者),Bayer AG, Med Affairs & Pharmacovigilance, Pharmaceut MA TA Womens Hlth Care, Bldg S101,10-244, D-13342 Berlin, Germany.
2022-3-21
Objective Levonorgestrel-releasing intrauterine devices (LNG-IUDs) and copper intrauterine devices (Cu-IUDs) offer long-acting contraception; however, some women may discontinue use within the first year due to bleeding pattern changes, limiting their potential. This systematic literature review investigated whether differences in bleeding profiles influence continuation rates in women in America, Europe and Australia. Methods Searches performed in PubMed and Embase were screened to identify publications describing bleeding patterns and rates of early IUC removal/discontinuation or continuation, descriptions of bleeding patterns, reasons for discontinuation, and patient satisfaction, acceptability and tolerability for LNG-IUDs and Cu-IUDs published between January 2010 and December 2019. The results were further restricted to capture citations related to 'Humans' and 'Females'. The review was limited to studies published from 2010 onwards, as changing attitudes over time mean that results of studies performed before this date may not be generalizable to current practice. Results Forty-eight publications describing 41 studies performed principally in the USA (n = 17) and Europe (n = 13) were identified. Publications describing bleeding patterns in LNG-IUD users (n = 11) consistently observed a reduction in bleeding in most women, whereas two of three studies in Cu-IUD users reported heavy bleeding in approximately 40% of patients. Rates of discontinuation for both devices ranged widely and may be as high as 50% but were lower for LNG-IUDs versus Cu-IUDs. Discontinuation rates due to bleeding were consistently higher for Cu-IUDs versus LNG-IUDs. Conclusions Bleeding is a common reason for discontinuation of Cu-IUDs and LNG-IUDs. The more favourable bleeding pattern observed in LNG-IUD users may be associated with a lower rate of early discontinuation of LNG-IUDs versus Cu-IUDs.
BMC WOMENS HEALTH
卷号:22|期号:1
收录类别:SCIE
语种
英语
来源机构
McMaster University; Case Western Reserve University; Case Western Reserve University Hospital; University Hospitals of Cleveland; Bayer AG
资助机构
Bayer AG(Bayer AG)
资助信息
This research was funded by Bayer AG.
被引频次(WOS)
2
被引频次(其他)
2
180天使用计数
0
2013以来使用计数
1
EISSN
1472-6874
出版年
2022-3-21
DOI
10.1186/s12905-022-01657-6
学科领域
循证公共卫生
关键词
Contraception Discontinuation Intrauterine device Menstrual bleeding Satisfaction
WOS学科分类
Public, Environmental & Occupational Health Obstetrics & Gynecology